Mem EATON 100 AMP 30mA DOUBLE POLE RCCB RCD A100HE

£9.9£99Clearance
ZTS2023's avatar
Shared by
ZTS2023
Joined in 2023
82
63

About this deal

You are right assuming as long as the electical characteristic match it will perform the same function..

The method of installation requires 30mA RCD protection – e.g. Regulation 415.1 & 522.6.202. Dedicated circuit feeding an immersion heater, conventional oven or cooker, with resistance heating elements. Type A RCDs are not designed to detect smooth dc residual currents. They will still trip within safe limits with < 6 mA smooth dc superimposed on a 50Hz pulsed residual current. Requirement for a transient resistance feature < 3 kA and short 10 ms time delay. **Note: Type A transient resistant RCDs only meet EN 61008/9 for general UK 50Hz residual currents.The method of installation relating to protective earthing will depend on the operational leakage current (protective conductor current) – see 543.7. The use of a 30mA RCD may be required for several reasons; cable installation, location / application area for the pump etc. Take note of 531.3.2 Operational leakage current (protective conductor current) for the circuit should not exceed 30% of the RCD sensitivity. So question one does it pass when tested with a RCD tester? If so what makes you think it is faulty? I am sure the one in my old house was tripping due to surges when a neighbour was welding. Two identical RCD's would hold for 18 months without a problem, then trip for seeming no reason for couple of weeks, then again two years no tripping. The fault current (If) contains mixed frequency components between 10Hz (minimum motor frequency) and 1kHz (maximum inverter switching frequency) ***.

If you’re not sure about quantities, sizes or have any other questions about your electrical wholesale products, our Electrical2Go sales team will be more than happy to help. Give them a call now on 01424 220384. KEY FEATURES Add to that the changes that have been imposed on the local supply networks i.e. green energy they have caused a situation that is going to result in frequent surges and transient voltages being produced all the time hence we now need to install surge protection or the likelihood is that if a surge occurs at a property and there is no surge protection then the blame will be passed on to the little man again. Type F RCDs are not designed to detect smooth dc residual currents. They will still trip within safe limits with < 10 mA smooth dc superimposed on a 50Hz pulsed residual current. Memera 2000AD – These have a narrow terminal and only fit boards specifically marked Memera 2000AD. They won't fit in older boards. I believe the article makes it clear that the their are 4 Types of RCD that may need to be considered - Quote from the article -The revised RCD guidance in 531.3.3 is precise. The appropriate Type of RCD must be selected, based on the characteristics of the residual current and the equipment that is likely to be connected to the RCD protected circuit". Would you be able to reveal the make and model of the RCD that trips, and the make and model of the smart meter?

Asda Great Deal

Free UK shipping. 15 day free returns.
Community Updates
*So you can easily identify outgoing links on our site, we've marked them with an "*" symbol. Links on our site are monetised, but this never affects which deals get posted. Find more info in our FAQs and About Us page.
New Comment