I was ready to go buy a new actuator as I believed this was the problem, however it appears to operate as described in the above discussion. Edit: I've just done some more investigating this morning. The problem of the pump continuing to run last night, doesn't appear to occur when I try it now. I unplugged the MPV and it caused the pump to switch off and the valve return to its default W. I do know they have a circuit board and very flimsy, but normally reliable, micro-switches but why would I want to go replacing the whole actuator, as you suggested in the first place, or even the circuit board as you now suggest, when the excellent descriptions of correct operation given by both 'Jonhmdc' and 'flameport' show that my actuator was working correctly all along and the only thing at fault was my understanding of its correct operation. When there is a CH demand but no HW demand (tank stat satisfied or HW off at programmer) the valve moves to the CH position. A microswitch in the valve actuator switches a live supply to the orange wire - which then powers the boiler and pump. I have a really weird problem with a Drayton MA1 mid-position valve and I can't find any reference to this specific problem.

One year ago (almost to the day) the Drayton MA1 mid-position actuator was replaced (4 years old) on my central heating system as it wasn't operating correctly. It was replaced with another MA1 and the problem was solved. However, I have just switched on my central heating for the first time this year and find that I always get CH with HW even when the CH timer is off. I looked at the MA1 and can see that the valve position is in the middle (HW+CH). If I unsnap the actuator from the valve I can turn the valve manually. I then tried the following with the MA1 removed: If heating or water is called for the main valve opens and the 3 position valve moves to Heat or Water. If both are called for then the Mid position is selected which allows water to circulate to both.One side of the house, the radiators do get hot, Some of the other radiators don't, or at least take a long time (I've only recently put the hot water on constant). Pump is on flat out setting. This suggests that the radiators may not be balanced. That was why I came here and my misunderstanding has now been corrected thanks to John and flameport! The problem with the cold shower remains a mystery, appears to be a one-off and it has not happened again. However, turning off the system power causes the actuator to return immediately to the W, relaxed, position under spring pressure. Turn on the system power and everything works as it should, until the Heating-only demand is satisfied when the actuator remains in H.

Anyway having diagnosed this far I'm going to leave it with the central heating and the water heating on full time to see if I can get the temperature in the bungalow up to the expected level.The MPV actuator is a BGMVSP-23. The control and thermostat is a Hive system. Boiler is a Worcester Greenstar Ri. System is gravity fed open vented system, tanks in the loft and HW cylinder in airing cupboard. Last night my partner heard a very strange buzzing whiring noise coming from what i now know is the "mid position actuator" . I have looked up the model and found it to be a "drayton mid position actuator MA1" and wanted to know what i need to do to replace it . So, am I trying to fix a problem that isn't there, (other than not having any hot water yesterday morning)? Perhaps I've never noticed the actuator staying in the H (or the last selected) position before. With the head unit removed from the valve body, turning on the system and demanding Heating causes the actuator to move to the H position. Turning down the room stat satisfies the demand and the system shuts down the boiler and the pump but the actuator remains in the H position. Cycling the demand fires the boiler and pump but satisfying the demand with the room-stat has no effect on the actuator which stubbornly remains in H.

Asda Great Deal

Free UK shipping. 15 day free returns.
Community Updates
*So you can easily identify outgoing links on our site, we've marked them with an "*" symbol. Links on our site are monetised, but this never affects which deals get posted. Find more info in our FAQs and About Us page.
New Comment