As a school is only occupied during the hours of daylight, emergency lighting is not therefore required. However, should the school be used out of hours, in the hall for example, then emergency lighting should be installed in the hall and the exit routes from it. The ‘responsible person’ should have the final say on this and might want to consult the local fire officer. The occupier/owner of the premises should appoint a competent person to supervise the testing of the system. This person shall be given sufficient authority to ensure the carrying out of any work necessary to maintain the system in correct operation. Competent can be defined as someone who has sufficient training and experience or knowledge and other qualities that allow them to maintain the system properly. The level of competence required will depend on the complexity of the situation and the particular help that is required.

Key Switch - Front Plate and Key Emergency Lighting Test Key Switch - Front Plate and Key

Five or six storey house converted to self-contained flats require conventional lighting and emergency escape lighting. Importantly, common escape routes should be well lit.

Delivery Options

An emergency lighting system should be installed by an electrician who specialises in emergency lighting. Now the refurbishment on the ground floor seems to be wired up in the 'new' way - does not extinguish power to mains. British Standard BS 5266-1: 2011 provides clear guidelines about the design and installation of emergency lighting. It should be remembered that the British Standards specify the best practice for standard situations, however, a higher standard may be required for a particular installation.

MK Metalclad Plus 20A 1-Gang DP Metal Clad Key Switch

Two, three or four storey houses converted to self-contained flats require conventional lighting and emergency escape lighting if the f ire risk assessment requires it. Borrowed lighting may be suitable in small premises (eg small shops) where there is light coming into the building from a dependable outside source, e.g. street lamps and will adequately illuminate escape routes. Alternatively, single ‘stand-alone’ escape lighting units may be sufficient in small premises and these can sometimes be combined with exit or directional signs. For residential properties landlords are deemed to be the ‘responsible person’ for all fire safety and emergency lighting. If sufficient open area emergency lighting is in the vicinity of a fire exit, non-illuminated fire exit signs can be sufficient in locations of minor importance. Photo-luminescent fire exit signs would be preferable in this case, although it has to be ensured that sufficient light is reaching the photo-luminescent sign to ensure it is ‘charged’ at all times. ConsiderationsThey would need to be conversant with BS 5266-1- 2011 Emergency lighting-Part 1: Code of practice for emergency lighting of premises. In my humble opinion the switch should be of "simulation" status IE cutting power (as it would if in a power cut, fire, etc.) and illuminating EL only. A test for the full duration (usually three hours) of the emergency lights must be carried out once a year. The emergency lights must still be working at the end of this test. The result must be recorded and, if failures are detected, these must be remedied as soon as possible.